Washer fills only with cold water regardless of temperature setting selected (Warm or Hot). The hot or warm solenoid port on the triple valve has failed internally.
Water continuously drips into the wash tub even when the machine is off and not in use. The valve port is stuck open, allowing water to leak through the diaphragm.
Machine fills to the wrong water level regardless of load size selected. The valve is not properly regulating water volume entering the tub.
Washing machine fails to blend hot and cold water when Warm cycle is selected, producing only cold or only hot water. The mixing solenoid port on the triple valve is defective.





💡 Pro Tip: How to Know If Your Triple Water Valve Has Failed
Your part is likely the culprit if you notice any of the following:
⚠️ Washer fills with cold water only — even when Warm or Hot is selected
⚠️ Constant dripping or water leaking into the tub when the washer is off
⚠️ Washer overfills or underfills regardless of the load size setting
⚠️ Water dripping through the funnel/shower-head assembly during idle cycles
🔍 Diagnostic Tip: First confirm hot water supply pressure is adequate and inlet screens are clean. Then use a multimeter to test solenoid coil continuity at each port (~120V expected). If one solenoid has continuity but the valve port still drips or stays closed, the internal diaphragm is stuck — replace the entire triple valve assembly.
📦 What's in the Box
✅ 1× Triple Water Inlet Valve Assembly (2-coil, 3-solenoid, 120V/60Hz, 5-5/8"L × 3-5/8"W × 2-3/4"H)
We typically respond within 1 business day. Include your appliance model number for the fastest answer.
Disclaimer: Compatibility information, part numbers, and model fitment data on this page are sourced from manufacturer databases and third-party references. While we strive for accuracy, please verify your appliance model number before ordering. Heima is not responsible for errors or omissions in compatibility listings.