Dryer drum spins normally but produces zero heat on any cycle — the blown high limit fuse has interrupted power to the heating element or gas burner.
Dryer is completely unresponsive or buzzes briefly when Start is pressed but the drum does not turn — a blown high limit fuse cuts motor power on some models.
Clothes require two or more full cycles to dry completely, indicating the fuse may be intermittently open or heat output is significantly reduced.
Drum interior or exhaust air is excessively hot before the fuse trips, signaling the high limit safety threshold has been reached and the fuse needs replacement.




💡 Pro Tip: How to Know If Your High Limit Thermal Fuse Is Blown
Your part is likely the culprit if you notice any of the following:
⚠️ Dryer runs but produces no heat at all
⚠️ Dryer will not start — drum stays completely still
⚠️ Dryer starts but buzzes slightly and stops immediately
⚠️ Clothes take multiple cycles to dry (partial blow)
Set your multimeter to continuity mode and probe both terminals of the fuse. A good fuse will beep or show near-zero resistance. If you read infinite resistance (OL), the fuse is open and must be replaced. Important: always investigate the root cause — a clogged exhaust vent or faulty high-limit thermostat is the most common reason this fuse blows. Clean the vent thoroughly before installing the new fuse to prevent repeat failure.
📦 What's in the Box
✅ 1× High Limit Thermal Fuse (1-1/4"L × 1-1/2"W × 2-1/4"H, trips at ~196°F / 91°C, metal/ceramic body)
We typically respond within 1 business day. Include your appliance model number for the fastest answer.
Disclaimer: Compatibility information, part numbers, and model fitment data on this page are sourced from manufacturer databases and third-party references. While we strive for accuracy, please verify your appliance model number before ordering. Heima is not responsible for errors or omissions in compatibility listings.