Dryer drum spins normally but produces no heat — the blown high-limit thermostat has permanently interrupted power to the heating element.
Dryer stops mid-cycle before clothes are fully dry because the thermostat is tripping too early due to age or marginal blockage.
If a related cycling thermostat has failed, the high-limit thermostat may be the only safety device preventing clothes or lint from scorching.
Repeated circuit breaker trips during operation can indicate the heating circuit is drawing excess current due to a failing thermostat.




💡 Pro Tip: Is Your High Limit Thermostat the Culprit?
Your part is likely the culprit if you notice any of the following:
⚠️ Dryer runs but produces no heat at all
⚠️ Dryer shuts off prematurely before clothes are dry
⚠️ Flashing error codes or heat-related indicator lights on control panel
⚠️ Household circuit breaker trips repeatedly during a drying cycle
🔎 Test with a multimeter set to continuity mode — at room temperature the thermostat should show continuity (closed circuit). An open reading confirms it has blown. Also check your vent hose for kinks or lint blockage; a clogged vent is the #1 cause of repeat thermostat failure.
📦 What's in the Box
✅ 1× High Limit Thermostat L200-30F (Two Male 1/4" Terminals, Flush Mount)
We typically respond within 1 business day. Include your appliance model number for the fastest answer.
Disclaimer: Compatibility information, part numbers, and model fitment data on this page are sourced from manufacturer databases and third-party references. While we strive for accuracy, please verify your appliance model number before ordering. Heima is not responsible for errors or omissions in compatibility listings.