Dryer drum tumbles but produces no heat — burned-out heating coil breaks the circuit entirely, causing cold air only.
Clothes require multiple cycles to dry; a partially failed coil cannot reach or sustain target drum temperature.
A shorted or intermittently failing element causes the thermal protection circuit to cut power before the cycle completes.
A shorted element coil may produce heat continuously even after the thermostat signals it to stop, causing excessive drum temperatures.
Arcing at a cracked coil or contact with the housing generates a distinct burning odor during operation.
💡 Pro Tip: How to Diagnose a Faulty Heating Element
Your part is likely the culprit if you notice any of the following:
⚠️ Dryer runs but produces no heat – drum tumbles cold
⚠️ Clothes take two or more cycles to dry completely
⚠️ Dryer overheats or shuts off mid-cycle unexpectedly
⚠️ Burning smell from the drum area during operation
🔍 Use a multimeter set to continuity mode: test each terminal of the element to the case. If you get continuity from a terminal to the metal housing, the element is shorted and must be replaced. Also check for a visible break in the coil wire. Always verify the thermal fuse on the blower housing first – a blown fuse is the #1 cause of no-heat calls and may have been triggered by a failing element.
📦 What's in the Box
✅ 1× 279838 Dryer Heating Element Assembly (5400W / 240V, flat-can housing with Ni-Cr coil and mica insulators)
We typically respond within 1 business day. Include your appliance model number for the fastest answer.
Disclaimer: Compatibility information, part numbers, and model fitment data on this page are sourced from manufacturer databases and third-party references. While we strive for accuracy, please verify your appliance model number before ordering. Heima is not responsible for errors or omissions in compatibility listings.
Reviews
There are no reviews yet.