Dryer drum spins normally but produces no heat — clothes remain damp after a full cycle. A burned-out element coil (open circuit) is a primary cause.
Dryer heats weakly; cycles take much longer than usual. A partially failed coil delivers insufficient wattage, extending drying time significantly.
A shorted element coil can cause the dryer to heat continuously without cycling off, triggering the hi-limit thermostat or tripping the circuit breaker.
The thermal fuse in the assembly has blown due to overheating (often from a blocked vent), cutting power to the element and shutting the dryer down prematurely.
With no heat being generated, the moisture sensor never satisfies, preventing the timer from advancing to the end of the cycle.
Samsung dryers display error code HE when a heating malfunction is detected. Replacing the full heating element assembly typically resolves this fault code.




💡 Pro Tip: Diagnosing a Failed Samsung Dryer Heating Element
Your part is likely the culprit if you notice any of the following:
⚠️ Dryer runs but produces no heat — clothes come out damp after a full cycle
⚠️ Drying times are significantly longer than normal due to reduced heat output
⚠️ Dryer overheats or runs continuously without cycling off (shorted element coil)
⚠️ Circuit breaker trips repeatedly during dryer operation
⚠️ Samsung error code HE displayed on the control panel
🔍 Diagnostic tip: With the dryer unplugged, set a multimeter to the resistance (Ω) setting and probe the two element terminals. A healthy coil reads approximately 10 ohms. An open circuit (OL) confirms a burned-out element. Also test each terminal to the metal housing — any continuity to the case means the coil is shorted and the assembly must be replaced. Remember: a blown thermal fuse is the #1 cause of no-heat — always test the fuse first before condemning the element.
📦 What's in the Box
✅ 1× DC97-14486A Heating Element Canister Assembly (240V / 5300W, 20" L × 5" dia.)
✅ 1× Built-in DC47-00019A Heating Element Coil (pre-installed)
✅ 1× DC47-00018A Hi-Limit Thermostat (L260-50, pre-installed)
✅ 1× DC96-00887A Thermal Fuse (pre-installed)
✅ Pre-attached Black & Blue Lead Wires
We typically respond within 1 business day. Include your appliance model number for the fastest answer.
Disclaimer: Compatibility information, part numbers, and model fitment data on this page are sourced from manufacturer databases and third-party references. While we strive for accuracy, please verify your appliance model number before ordering. Heima is not responsible for errors or omissions in compatibility listings.
Reviews
There are no reviews yet.