Dryer drum spins normally but no heat is produced — the igniter has failed to draw sufficient current to open the gas valve and light the burner.
Clothes remain damp after a full cycle because the igniter is weak and only intermittently ignites the burner, producing inconsistent heat.
Gas hiss is audible but no flame appears; the igniter glows for over 90 seconds without igniting — a classic sign of a worn-out silicon carbide element.
The dryer starts and then stops heating partway through, caused by a degraded igniter that fails to hold the gas valve open consistently.
💡 Pro Tip: Is Your Gas Dryer Igniter the Problem?
Your part is likely the culprit if you notice any of the following:
⚠️ Dryer runs and tumbles normally but produces no heat at all
⚠️ You hear a clicking or hissing sound but the burner never lights
⚠️ Igniter glows red for more than 90 seconds without igniting the gas flame
⚠️ Multimeter test shows no continuity across the igniter terminals
Test tip: Set your multimeter to the Rx1 setting and probe both igniter terminals. A healthy igniter reads between 50–400 ohms. A reading of OL (open) or infinite resistance means the igniter has failed and must be replaced. Also visually inspect for cracks in the ceramic body — a cracked igniter will not draw enough current to open the gas valve.
📦 What's in the Box
✅ 1× Flat Silicon Carbide Gas Dryer Igniter (3-1/2"L × 1-1/4"W × 5/8"H, 3.4–3.6A)
✅ 1× Wire Harness with Plug (5-1/8"L)
✅ 1× Mounting Bracket
We typically respond within 1 business day. Include your appliance model number for the fastest answer.
Disclaimer: Compatibility information, part numbers, and model fitment data on this page are sourced from manufacturer databases and third-party references. While we strive for accuracy, please verify your appliance model number before ordering. Heima is not responsible for errors or omissions in compatibility listings.
Reviews
There are no reviews yet.