Unplug washer and shut off water supply valves before starting. Residual water in lines will drain when hoses are disconnected.

Water pooling behind your GE washer? That's usually the triple inlet valve leaking at the connections. The WH13X10033 controls hot, cold, and spray water lines—and when those solenoids or seals fail, you'll see puddles on the floor or slow fill times. This guide walks you through replacing it on models like GWRE6270H0WW, WCRE6270H1CC, and WHRE5550H2WW.
What You Need Before Starting
- Phillips screwdriver
- 1/4" nut driver or socket wrench
- Adjustable pliers
- Bucket or towels (for residual water)
- New WH13X10033 triple inlet valve
Repair Time: 25-35 minutes
Difficulty: Moderate — You'll need to access the back panel and work with water connections.
Safety First
Unplug the washer completely before starting. Turn off both hot and cold water supply valves behind the machine—these are usually quarter-turn handles. Even after shutting off water, some will drain from the inlet valve when you disconnect hoses, so keep that bucket handy. Don't skip this step or you'll flood your laundry room.
Step 1: Access the Water Inlet Valve
Pull the washer away from the wall to access the back panel. On most GE front-loaders like the GWRE6270 series, you'll see the inlet valve at the top back—three water line connections visible where your fill hoses attach. Use your adjustable pliers to loosen the hose connections at the valve (not at the wall). Water will drip out, so position your bucket underneath.
Step 2: Disconnect Internal Hoses and Wiring
Inside the cabinet, three rubber hoses connect from the valve to the dispenser and tub. Use your 1/4" nut driver to loosen the spring clamps holding these hoses—slide the clamps back, then twist and pull the hoses off. The electrical harness plugs into the valve with a tab-lock connector. Press the release tab and pull straight out. Don't yank on the wires themselves.
Step 3: Remove Mounting Screws and Old Valve
Two Phillips screws secure the valve bracket to the washer frame. Remove these and the old WH13X10033 lifts right out. Check the mounting area for mineral buildup or corrosion—wipe it clean before installing the new valve. This prevents leaks at the seal points.
Step 4: Install the New Triple Inlet Valve
Position the new WH13X10033 valve in the bracket, aligning the mounting holes. Secure with the two Phillips screws—snug but not overtightened (you'll crack the plastic housing). Reconnect the electrical harness until you hear the tab click. Then reattach the three internal hoses, sliding the spring clamps back into position about 1/2" from the hose ends.
Step 5: Reconnect External Water Lines
Thread your hot and cold supply hoses back onto the valve ports. The WH13X10033 has three inlets—hot on the left, cold on the right, and the center port feeds the spray system. Hand-tighten first, then use pliers to snug another quarter-turn. Don't crank down hard or you'll strip the threads. Push the washer back into place, turn on the water valves, and plug it in.
Testing After Installation
Run a rinse cycle and watch the valve area for leaks. You should hear three distinct clicks as the solenoids open during fill—that's normal operation. Check all hose connections (both inside and outside) for drips. If water seeps from where a hose connects to the valve, tighten that connection another eighth-turn. The valve should fill the tub smoothly without slow trickles or puddles forming behind the machine.
Frequently Asked Questions
Why does my GE washer fill slowly even with a new inlet valve?
Check the inlet screens inside the hose connections—they catch sediment and restrict flow when clogged. Unscrew the supply hoses and you'll see small mesh filters. Rinse them under water or replace if damaged. Low home water pressure (below 20 psi) can also cause slow fills that aren't the valve's fault.
Can I replace just one solenoid instead of the whole WH13X10033 valve?
GE doesn't sell individual solenoids for this triple valve assembly. You'll need to replace the entire unit. Trying to repair internal solenoids usually causes more leaks because the valve body seals degrade over time anyway. The complete replacement gives you fresh solenoids and new seals at all three ports.
Will this valve work on both top-load and front-load GE washers?
The WH13X10033 is designed for specific GE front-load models like the GWRE, WCRE, and WHRE series listed in the compatibility chart. It won't fit most top-loaders, which use different valve configurations. Always verify your model number against the parts compatibility list before ordering—even within GE's lineup, valve designs vary by washer generation.
Clean mineral deposits from the mounting area before installing the new valve to ensure proper sealing at hose connections.
Need the part for this repair?
WH13X10033 · In Stock · Ships next business day