How to Replace 3390719 Thermal Fuse on Whirlpool & Maytag Dryers — Step-by-Step
Unplug dryer completely before starting. Allow heating components to cool for 10 minutes if recently used.

Your Maytag MED5900TW0 runs for five minutes, then stops cold. Drum spins, timer advances, but zero heat. You reset the breaker — nothing changes. That clicking sound near the blower housing? That's your 3390719 thermal fuse telling you it's done its job protecting your dryer from overheating, and now it needs replacing.
This thermal fuse is a one-shot safety device rated at 91°C. Once it blows, you can't reset it — replacement is the only fix. The good news? It's one of the easiest dryer repairs you'll tackle, and you'll have heat again in under 30 minutes.
What You Need Before Starting
Grab these tools from your garage:
- Phillips and flathead screwdrivers
- 1/4" socket set (for rear panel screws)
- Work gloves (metal edges are sharp)
- Multimeter — optional but helpful for confirming the blown fuse
Repair Time: 15-30 minutes
Difficulty: Easy
Safety First
Unplug your dryer completely. If it's hardwired or you can't reach the plug, flip the breaker at your electrical panel. Gas dryers? Shut off the gas valve too. You're working near the heating element and blower — give yourself 10 minutes for components to cool if you just ran a load. The metal housing retains heat longer than you'd think.
Step 1: Remove the Lower Front Panel or Rear Access Panel
Most Whirlpool and Maytag models like the WED8500BW0 or MEDB850YG1 have the thermal fuse mounted on the blower housing, accessible from the rear. Use your socket set to remove 6-8 screws around the back panel perimeter. Some Kenmore models use the front lower panel instead — two screws at the bottom corners, then lift and pull toward you.
Step 2: Locate the Thermal Fuse on the Blower Housing
Look for a small white or cream-colored component about 1 inch long, attached to the blower housing with two wire terminals. On the YMEDB980BG0, it's on the right side of the round metal blower. The 7MWGD7800XW0 has it dead center. It's always near where hot air exits the drum. You'll see lint buildup around this area — that's usually why it blew in the first place.
Step 3: Disconnect and Remove the Old Fuse
Pull the two wire terminals straight off — they slide on like spade connectors. No twisting needed. Now remove the single screw or metal clip holding the fuse to the housing. Some models use a spring clip instead of a screw. The old fuse will come right out. If you've got a multimeter, test it: set to continuity, touch the probes to each terminal. No beep? It's blown, just like you suspected.
Step 4: Install the New 3390719 Fuse
Position your new fuse exactly where the old one sat — the mounting hole will line up. Secure it with the screw or clip. Push the wire terminals onto the new fuse tabs until they click. They're keyed, so they only go on one way. Give each wire a gentle tug. If it pulls off, you didn't seat it fully.
Step 5: Clean the Vent and Reassemble
Before you button everything up, pull out that flexible vent hose and shake out the lint. Run a dryer vent brush through if you've got one. A clogged vent is why your fuse blew — restricted airflow makes the dryer overheat. Reattach the rear panel with all screws, plug in the dryer, and run a test cycle with damp towels.
Testing After Installation
Start a normal cycle and listen. Within two minutes, you should feel warm air at the vent exhaust outside. Check the drum — clothes getting hot? You're golden. If the dryer still won't heat, you've likely got a blown heating element or bad cycling thermostat. But 9 times out of 10, replacing this fuse solves it. As one customer said: "Made it work good" — and that's exactly what you'll experience.
Frequently Asked Questions
Why does my thermal fuse keep blowing on my Whirlpool dryer?
Restricted airflow is the number one cause. Check your vent hose for kinks, clean the lint trap housing with a vacuum, and make sure the exterior vent flap opens freely. A cycling thermostat that's stuck closed can also cause repeated fuse failures by letting the dryer run too hot. If you've replaced this fuse twice in six months, dig deeper into your venting system.
Can I bypass the thermal fuse to test my dryer?
Technically yes, but don't leave it that way. The fuse prevents fires when your dryer overheats. Jump it with a wire to confirm the fuse is your problem, run one test load, then install the proper replacement. Models like the GEW9878PG0 won't start at all with a blown fuse, so testing helps rule out control board issues.
Will this 3390719 fuse fit my Kenmore 110 series dryer?
Most Kenmore 110 series dryers manufactured by Whirlpool use this exact fuse. Check your model number against the compatibility list — if you see 4KMED5900TW0 or similar Kenmore models, you're good. The WP3390719 supersedes several older part numbers including 3389639 and 688841, so if your original fuse has one of those numbers stamped on it, this replacement works perfectly.
Clean your dryer vent thoroughly when replacing the thermal fuse — restricted airflow is the main reason these fuses blow.