How to Replace WH13X24386 Water Inlet Valve on GE Top Load Washer — Step-by-Step
Always unplug washer before working on electrical components. Water and electricity don't mix — turn off both water supply valves before disconnecting hoses.

You start a load of laundry, walk away, and come back to find water pooling behind your GE washer. Or maybe the tub fills painfully slow, or you're getting cold water when you selected hot. Nine times out of ten, that's your water inlet valve calling it quits. The WH13X24386 controls water flow into your washer, and when it fails, you'll know immediately.
What You Need Before Starting
This is a straightforward replacement that most homeowners can handle in about 45 minutes. Here's what you'll need:
- Phillips screwdriver
- 1/4-inch nut driver or socket set
- Bucket or towels (for residual water)
- Pliers (needle-nose work best)
- Your new WH13X24386 valve assembly
Difficulty: Easy to Moderate | Time: 30-45 minutes
Safety First
Unplug your washer completely — don't just turn off the water. You'll be working near electrical connections, and even residual voltage can give you a nasty shock. Turn off both hot and cold water supply valves behind the machine. Have a bucket handy because there's always leftover water in the lines, even after you disconnect them.
Step 1: Access the Back Panel
Pull your washer away from the wall to give yourself working room. Disconnect both water supply hoses from the back of the machine — expect water to dribble out, that's normal. You'll see the inlet valve mounted near the top of the back panel. On models like the GTW460ASJAWW and GTW465ASN series, it's held in place by two or three screws and the hose connections.
Step 2: Disconnect the Wire Harness
Before removing any screws, disconnect the wire harness from the valve. There are typically two solenoid connectors — squeeze the locking tabs and pull straight off. Don't yank on the wires themselves. Take a quick photo with your phone if you're worried about reconnecting them later, though they're keyed and only fit one way.
Step 3: Remove the Old Valve
Remove the mounting screws holding the valve to the frame. On most GE top-loaders like the GTW490ACJ series, there are two screws at the top. Once those are out, you'll need to disconnect the internal hoses that run from the valve to the dispenser and tub. These are typically held by spring clamps — use pliers to squeeze and slide them back, then twist and pull the hoses off. Have your bucket ready.
Step 4: Install the New WH13X24386 Valve
Position your new valve in the same orientation as the old one — the inlet ports should face outward where your supply hoses connect. Reattach the internal hoses first, sliding those spring clamps back into position. Then secure the valve with the mounting screws. Connect the wire harness to the solenoid coils — you'll hear them click when they're seated properly.
Step 5: Reconnect Water Supply and Test
Thread your water supply hoses back onto the valve — hand-tight plus a quarter turn with pliers is plenty. Turn on the water supply valves and check for leaks around the connections. Plug the washer back in and run a small test load. The tub should fill normally with the correct water temperature when you select hot, cold, or warm.
Testing After Installation
Run a rinse and spin cycle first — no clothes, just water. Watch the back of the machine for any leaks during the fill cycle. Check that hot water actually comes out hot and cold stays cold. If you're still getting only cold water or the washer won't fill at all, double-check your wire connections. The solenoids need solid electrical contact to open the valve.
Frequently Asked Questions
Why is my washer leaking from the back after I replaced the valve?
The most common culprit is the supply hose connections. Make sure the rubber washers inside your hoses aren't cracked or missing — those create the seal. Also check that the internal hoses to the dispenser are fully seated with the spring clamps in place. A loose clamp will leak every time the washer fills.
Can a bad inlet valve cause my washer not to spin?
Not directly, but if the valve fails and the washer can't detect proper water level, it may refuse to advance to the spin cycle. Most GE washers have pressure switches that won't let the cycle continue if water level isn't right. Fix the inlet valve first — that often solves what seems like a spin problem.
Will this valve work if my washer is filling too slowly?
If the valve is clogged or the solenoids are weak, yes, replacing it will fix slow fill times. But first check your water pressure at the wall valves — they should be fully open. Also inspect the inlet screens on the valve itself for debris. Sometimes cleaning those screens is all you need, but if the solenoids are failing, the WH13X24386 replacement is your answer.
Take a photo of wire connections before disconnecting anything. Those solenoid connectors look similar, and while they're keyed, a photo saves you troubleshooting time later.
Need the part for this repair?
WH13X24386 · In Stock · Ships next business day