Dryer drum does not turn and machine will not power on — blown thermal limiter breaks the circuit
Dryer runs normally but produces no heat during the cycle
Dryer stops abruptly before the cycle completes
Clothes remain damp after a full cycle due to insufficient heat
Dryer cabinet feels excessively hot to the touch during operation
💡 Pro Tip: How to Know Your Thermal Limiter Has Failed
Your part is likely the culprit if you notice any of the following:
⚠️ Dryer won't start at all — thermal fuse blown, circuit open, cannot be reset
⚠️ Dryer runs but produces no heat
⚠️ Dryer stops abruptly mid-cycle
⚠️ Dryer takes too long to dry clothes or feels excessively hot
🔍 Use a multimeter set to continuity mode — a blown thermal limiter will show no continuity (open circuit). Also check for a clogged lint filter or restricted vent duct, since blocked airflow is the #1 cause of repeated limiter failures. If the limiter keeps blowing, suspect a faulty cycling thermostat (part 131298300) as the root cause.
📦 What's in the Box
✅ 1× Dryer Thermal Limiter / Thermal Fuse 134120900 (220°F trip point, fits gas & electric)
We typically respond within 1 business day. Include your appliance model number for the fastest answer.
Disclaimer: Compatibility information, part numbers, and model fitment data on this page are sourced from manufacturer databases and third-party references. While we strive for accuracy, please verify your appliance model number before ordering. Heima is not responsible for errors or omissions in compatibility listings.
Reviews
There are no reviews yet.