Troubleshooting

Whirlpool Refrigerator Won't Start After Power Outage — 5 Causes & How to Fix

7 min read
May 24, 2026
Multiple root causes covered
Most common cause
Failed compressor start device (relay)
Avg repair cost
$50–$150
DIY difficulty
Moderate
Symptom checklist
Compressor won't start
Complete silence from compressor, no startup hum or clicking
Clicking every few minutes
Compressor attempts to start repeatedly but fails each time
Fridge dead after power outage
Refrigerator won't restart following electrical event or unplugging
Lights work but no cooling
Interior light functions normally but compressor never runs
Burnt plastic smell from back
Electrical burning odor near compressor area
Root cause analysis
W10613606 W10613606 Compressor Start Device & Capacitor Compatible with Whirlpool Maytag KitchenAid Amana Kenmore, Replaces AP5787784 W10416065 67003186 PS8746522

You walk into the kitchen Monday morning and something's off. The refrigerator is silent. No hum, no compressor running, just dead quiet. Maybe the power flickered during last night's storm, or maybe you unplugged it to move something. Either way, your Whirlpool fridge won't start, and everything inside is getting warmer by the hour.

When a refrigerator compressor won't kick on after a power interruption, the culprit is usually the start device or capacitor — the components that give your compressor the electrical jolt it needs to fire up. The W10613606 is a combined start device and capacitor assembly that fails more often than most homeowners realize, especially on models like the GX5FHDXTB01, EB9FVBLVS00, and GB2SHDXPB01.

Quick Symptom Check

Before you pull the fridge out from the wall, verify these symptoms:

  • Complete silence — No compressor hum, no clicking sounds
  • Lights work — Interior light comes on when you open the door, proving power is reaching the unit
  • Condenser fan runs — You might hear the fan under the fridge, but no compressor
  • Recent power event — Outage, brownout, or you unplugged it recently
  • Clicking from the back — Compressor tries to start every few minutes but can't

If three or more apply, you're likely dealing with a start device or capacitor failure. Let's walk through each cause from most to least common.

Cause #1: Failed Compressor Start Device (Relay)

Probability: 65%

The start device (also called a relay) is a small black component that clips onto the compressor. It gives the compressor windings the initial boost needed to start spinning. These fail in two ways: the internal contacts weld together from arcing, or they burn out and stop conducting entirely.

After a power surge or outage, the sudden voltage spike often fries this relay. On Whirlpool models using the W10613606, you'll see scorch marks or smell burnt plastic when the relay fails catastrophically.

How to diagnose:

  1. Unplug the refrigerator and wait 5 minutes
  2. Pull the fridge away from the wall — you need rear access
  3. Remove the lower rear access panel (usually 2-4 screws)
  4. Locate the compressor (big black cylinder) and find the start device clipped to its side
  5. Pull the start device off — it should slide straight off the terminals
  6. Shake it gently near your ear — if you hear rattling, the relay is toast
  7. Look for visible burn marks, melted plastic, or a burnt smell

If the relay rattles or shows burn damage, it's dead. The W10613606 assembly includes both the relay and capacitor as a single unit, so you'll replace both together.

Cause #2: Blown Run Capacitor

Probability: 25%

The run capacitor stores electrical energy and releases it to keep the compressor running smoothly. When capacitors fail, they either bulge visibly at the top, leak oil, or test out of spec with a multimeter.

Power surges kill capacitors fast. The sudden voltage spike exceeds the capacitor's rating, causing internal breakdown. On the W10613606 assembly, the capacitor is the cylindrical component attached to the relay housing.

How to diagnose:

  1. With power disconnected, inspect the capacitor visually
  2. Look for a bulging or domed top (should be flat)
  3. Check for oil residue around the base
  4. If you have a multimeter with capacitance testing, check the reading against the label spec (typically 88-108 µF)
  5. A reading 20% outside the range means replacement

Even if the capacitor looks fine, replacing it with the start device makes sense — they're sold together in the W10613606 kit, and both components wear from the same electrical stress.

Cause #3: Compressor Overload Protector Tripped

Probability: 8%

The overload protector is a thermal switch attached directly to the compressor body. If the compressor overheats or draws too much current, this protector opens the circuit to prevent damage. Sometimes it trips during a power event and won't automatically reset.

How to diagnose:

  1. Locate the overload — it's a small disc or rectangular component on the compressor near the start device
  2. Touch it carefully — if it's hot, it's still tripped
  3. Wait 30 minutes for it to cool completely
  4. Plug the fridge back in and see if it starts
  5. If it starts briefly then stops again, the compressor is drawing too much current (bigger problem)

If the overload keeps tripping repeatedly, don't keep resetting it. The compressor itself may be failing, and running it will cause more damage.

Cause #4: Seized or Failing Compressor

Probability: 5%

Sometimes the compressor itself is the problem. Internal bearings seize, windings short out, or mechanical damage prevents the motor from turning. This is worst-case because compressor replacement costs $400-600 in parts and labor — often more than the fridge is worth.

How to diagnose:

  1. With the start device removed, locate the three compressor terminals
  2. Set your multimeter to ohms (resistance)
  3. Test between each pair of terminals — you should get readings between 2-20 ohms
  4. Test from each terminal to the compressor housing (ground) — should read infinite (OL)
  5. If any terminal reads 0 ohms to ground, the compressor windings are shorted
  6. If readings between terminals are wildly different or infinite, windings are open

A seized compressor sometimes makes a hard humming sound or trips the breaker when you try to start it. If you hear loud humming for more than 3 seconds when plugged in, unplug immediately — that's the motor trying to turn against mechanical resistance.

Cause #5: Control Board Power Supply Issue

Probability: 2%

On newer Whirlpool models with electronic controls, the main control board sends power to the compressor relay. If the board's relay output fails, the compressor never gets the start signal even though everything else works fine.

How to diagnose:

  1. Check if other functions work normally — ice maker, water dispenser, temperature display
  2. Look for error codes on the display panel
  3. With a voltmeter, check for 120V at the compressor relay terminals when the fridge should be running
  4. No voltage means the control board isn't sending power

Control board diagnosis gets complex fast. If you've eliminated the start device, capacitor, and compressor as causes, and you're comfortable with electrical testing, you can troubleshoot the board. Otherwise, this is pro territory.

Step-by-Step: Replacing the W10613606 Start Device & Capacitor

If you've diagnosed the start device or capacitor as the problem, replacement takes about 15 minutes:

  1. Unplug the refrigerator — Not just "make sure it's off," physically disconnect power
  2. Access the compressor — Remove the lower rear panel
  3. Discharge any stored energy — Touch a screwdriver across the capacitor terminals (with insulated handle)
  4. Photograph the wiring — Take a clear photo before disconnecting anything
  5. Remove the old assembly — Pull the start device straight off the compressor terminals, then disconnect the wires to the capacitor
  6. Install the new W10613606 — Push the relay firmly onto the compressor terminals until it clicks, then connect the capacitor wires matching your photo
  7. Secure everything — Make sure no wires touch moving parts or hot surfaces
  8. Replace the panel — Reinstall the rear access cover
  9. Plug in and test — The compressor should start within 30 seconds

Listen for the compressor startup sound — a brief click followed by a steady low hum. If it starts and runs for 5 minutes without stopping, your repair worked.

When to Call a Pro

Call a technician if:

  • The compressor hums loudly but won't start after replacing the start device
  • The breaker trips immediately when you plug the fridge in
  • You smell burning or see smoke from the compressor area
  • The compressor starts but stops after 10-15 seconds repeatedly
  • Your multimeter tests show shorted compressor windings

These symptoms indicate compressor failure, which requires specialized equipment and refrigerant handling certification. Repair costs often exceed $500, so get a quote before approving work — replacement might be more economical.

Preventing Future Failures

To protect your investment after replacing the W10613606:

  • Install a surge protector — Use a whole-home suppressor or a quality appliance-grade surge strip
  • Wait 5 minutes after power loss — Never immediately plug in a fridge after an outage; let refrigerant pressure equalize
  • Check voltage — If lights dim when the compressor starts, your home may have voltage issues worth investigating
  • Keep coils clean — Dust buildup forces the compressor to work harder, shortening component life

Frequently Asked Questions

Can I replace just the start relay without the capacitor?

Technically yes, but it's not recommended. The W10613606 is sold as a matched set because both components typically fail around the same time, especially after electrical events. Replacing just one means you'll likely be back inside the fridge replacing the other within months. The labor to access the compressor twice costs more than buying the complete assembly once.

Why does my fridge work fine for a few hours then stop?

This pattern suggests the overload protector is cycling — the compressor runs, overheats, shuts off, cools down, then repeats. Common causes include a weak start capacitor (compressor struggles to start, drawing excess current), dirty condenser coils (poor cooling causes overheating), or early-stage compressor failure. Start by replacing the W10613606 and cleaning the coils. If cycling continues, the compressor itself is likely failing.

Is the W10613606 compatible with Kenmore refrigerators?

Yes, many Kenmore refrigerators are manufactured by Whirlpool and use identical components. The W10613606 replaces part numbers W10416065, 67003186, AP5787784, and PS8746522, which appear in both Whirlpool and Kenmore service manuals. Check your model number against the compatibility list — Kenmore models in the 253, 596, and 795 series commonly use this part. If your current part matches one of those replacement numbers, the W10613606 will fit.

Diagnosed the problem?

W10613606 · In Stock · Fast shipping

Shop W10613606 →
Likely parts needed
W10613606
W10613606 Compressor Start Device & Capacitor Compatible with Whirlpool Maytag KitchenAid Amana Kenmore, Replaces AP5787784 W10416065 67003186 PS8746522